Cali-GrafCali-Graf
String inverterCPS (Chint Power Systems)

CPS (Chint Power Systems) SCA50K-T-US-208

String inverter. 1 model, 50 kW AC at 208 V.

UL 1741 SBCEC listed · Oct 13, 2025
  • Rated AC power50 kW
  • CEC weighted efficiency96.5%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
SCA50K-T-US-208: max DC 700 V · MPPT 200–700 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V7–14—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V7–14—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V8–17—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V8–17—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V8–17—
Silfab Solar SIL-440QD440 W41.1 V28 V8–17—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V8–16—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V8–16—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V5–10—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V8–17—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V8–16—
Tesla TSP-420420 W43.4 V27.7 V8–16—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 50 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
CPS (Chint Power Systems) SCAxxK-T-US-20850 kW–50 kW96.5%200–700 VYes20250
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Yaskawa Solectria Solar PVI-xxTL-20825 kW–50 kW96.5%200–850 VYes2025—
Solis (Ginlong Technologies) S5-GC60K-LV-US60 kW–60 kW98.0%400–650 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About CPS (Chint Power Systems)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

CPS SCAxxKTL-DO/US-480 · 3 permitsCPS SCAxxKTL-DO-R/US-480 · 1 permitsCPS SCAxxKTL-DO/US-208 · 1 permitsSCAxxxK-T-US-480SCHxxxK-T-US-480SCHxxxK-T-US-600CPS SCHxxxKTL-DO/US-800CPS SCHxxxKTL-DO/US-480

Questions & answers

How efficient is the CPS (Chint Power Systems) SCAxxK-T-US-208?

The California Energy Commission lists a weighted efficiency of 96.5% for CPS (Chint Power Systems) SCAxxK-T-US-208 models, measured at six power levels and three DC voltages.

Is the CPS (Chint Power Systems) SCAxxK-T-US-208 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the SCA50K-T-US-208’s DC input voltage range?

CEC tested it at 200–700 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).