Cali-GrafCali-Graf
String inverterCPS (Chint Power Systems)

CPS (Chint Power Systems) CPS SCA50KTL-DO/US-480

String inverter. 3 models, 36 kW–60 kW AC at 480 V.

UL 1741 SBCEC listed · Aug 1, 2017Installed in 3 SoCal permits
Model
  • Rated AC power50 kW
  • CEC weighted efficiency98.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · building permits · 3 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SBIn permits
CPS SCA36KTL-DO/US-48036 kW480 V36 kW36 kW97.5%400–850 VFeb 1, 2023SB—
CPS SCA50KTL-DO/US-48050 kW480 V50 kW50 kW98.5%480–850 VAug 1, 2017SB2
CPS SCA60KTL-DO/US-48060 kW480 V60 kW60 kW98.5%540–850 VAug 1, 2017SB2

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
CPS SCA50KTL-DO/US-480: max DC 850 V · MPPT 480–850 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V16–17—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V16–17—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V19–21—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V19–21—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V18–20—
Silfab Solar SIL-440QD440 W41.1 V28 V18–20—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V18–20—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V18–20—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V11–12—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V19–21—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V18–20—
Tesla TSP-420420 W43.4 V27.7 V18–19—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Installed in Southern California

building permits
3
Permits name it
Sep 2024 – Jan 2026
2
Jurisdictions so far
LA County (unincorp.) (2), San Diego County (1)
286.5 kW
Typical system
median of 3 permits

Permits over time

1Sep ’2400Nov10Jan ’2500Mar00May00Jul00Sep00Nov01Jan ’26permits per month

Model named in permit

CPS SCA60KTL-DO/US-480
2
CPS SCA50KTL-DO/US-480
2
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Compare with similar 50 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-48036 kW–60 kW98.5%480–850 VYes20234
SolarEdge SExKUS9 kW–330 kW99.0%100–1,400 V16 of 19202514
SMA STP xx-US-8027.5 kW–70 kW97.5%300–850 VYes2026—
Yaskawa Solectria Solar PVI xxTL-48036 kW–100 kW98.5%340–850 V3 of 42025—
SMA SHP FLEX-US-2155 kW–172 kW99.0%372–1,200 VYes2025—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About CPS (Chint Power Systems)

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

CPS SCAxxKTL-DO-R/US-480 · 1 permitsCPS SCAxxKTL-DO/US-208 · 1 permitsSCAxxK-T-US-208SCAxxxK-T-US-480SCHxxxK-T-US-480SCHxxxK-T-US-600CPS SCHxxxKTL-DO/US-800CPS SCHxxxKTL-DO/US-480

Questions & answers

How efficient is the CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-480?

The California Energy Commission lists a weighted efficiency of 97.5–98.5% for CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-480 models, measured at six power levels and three DC voltages.

What sizes does the CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-480 come in?

The CEC list includes 3 models from 36 kW to 60 kW AC: CPS SCA36KTL-DO/US-480, CPS SCA50KTL-DO/US-480, CPS SCA60KTL-DO/US-480.

Is the CPS (Chint Power Systems) CPS SCAxxKTL-DO/US-480 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the CPS SCA50KTL-DO/US-480’s DC input voltage range?

CEC tested it at 480–850 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Sep 2024 – Dec 2024); San Diego County (Jan 2026). Equipment matched from permit descriptions by model number.