String inverterABB

ABB UNO-DM-3.8-TL-PLUS-US-SB-RA-Q

String inverter. 6 models, 3.3 kW–4.6 kW AC at 208 V / 240 V.

CEC listed · Aug 21, 2020Rapid shutdown
Model
  • Rated AC power3.8 kW
  • CEC weighted efficiency96.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 6 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
UNO-DM-3.3-TL-PLUS-US-SB-RA-Q3.3 kW208 V3 kW3 kW96.0%200–480 VAug 21, 2020—
UNO-DM-3.3-TL-PLUS-US-SB-RA-Q3.3 kW240 V3.3 kW3.3 kW96.5%200–480 VAug 21, 2020—
UNO-DM-3.8-TL-PLUS-US-SB-RA-Q3.8 kW208 V3.3 kW3.3 kW96.0%200–480 VAug 21, 2020—
UNO-DM-3.8-TL-PLUS-US-SB-RA-Q3.8 kW240 V3.8 kW3.8 kW96.5%200–480 VAug 21, 2020—
UNO-DM-4.6-TL-PLUS-US-SB-RA-Q4.6 kW208 V4.2 kW4.2 kW96.0%200–480 VAug 21, 2020—
UNO-DM-4.6-TL-PLUS-US-SB-RA-Q4.6 kW240 V4.6 kW4.6 kW96.5%200–480 VAug 21, 2020—

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

CEC Grid Support Inverter List (Oct 7, 2026)

Monitoring & communication

CEC Grid Support Inverter List (Oct 7, 2026)

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
UNO-DM-3.8-TL-PLUS-US-SB-RA-Q: max DC 480 V · MPPT 200–480 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc coldVmp hotPanels per stringInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 V30.6 V7–9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 V30.6 V7–9—
LONGi LR5-54HABB-400M400 W39.3 V25.3 V8–12—
JA Solar JAM54S31-405/MR405 W39.4 V25.5 V8–12—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 V27 V8–11—
Silfab Solar SIL-440QD440 W41.1 V28 V8–11—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 V28 V8–11—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 V28 V8–11—
REC Group REC460AA Pure-RX460 W68.8 V47.1 V5–6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 V25.3 V8–12—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 V28 V8–11—
Tesla TSP-420420 W43.4 V27.7 V8–11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 3.8 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
ABB UNO-DM-x.x-TL-PLUS-US-SB-RA-Q3.3 kW–4.6 kW96.5%200–480 V—20200
Tesla 1534000-xx-y3.34 kW–3.8 kW97.5%270–480 VYes20214
GoodWe GEPx.x-1-US304.33 kW–11.4 kW97.0%143–500 VYes2022—
GoodWe GWxxxx-MS-US304.33 kW–9.6 kW97.0%143–500 VYes2022—
GoodWe GWxxxxA-MS5 kW–9.6 kW97.5%210–480 VYes2021—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About ABB

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

PVS-xx-TL-R-USPVS-xx-TL-S-R-USPVS-xx-TL-SC-R-USUNO-DM-5.0-TL-PLUS-US-SZ-RA-UUNO-DM-x.x-TL-PLUS-US-SB-RA-QU

Questions & answers

How efficient is the ABB UNO-DM-x.x-TL-PLUS-US-SB-RA-Q?

The California Energy Commission lists a weighted efficiency of 96.0–96.5% for ABB UNO-DM-x.x-TL-PLUS-US-SB-RA-Q models, measured at six power levels and three DC voltages.

What sizes does the ABB UNO-DM-x.x-TL-PLUS-US-SB-RA-Q come in?

The CEC list includes 6 models from 3.3 kW to 4.6 kW AC: UNO-DM-3.3-TL-PLUS-US-SB-RA-Q, UNO-DM-3.3-TL-PLUS-US-SB-RA-Q, UNO-DM-3.8-TL-PLUS-US-SB-RA-Q, UNO-DM-3.8-TL-PLUS-US-SB-RA-Q, UNO-DM-4.6-TL-PLUS-US-SB-RA-Q, UNO-DM-4.6-TL-PLUS-US-SB-RA-Q.

Is the ABB UNO-DM-x.x-TL-PLUS-US-SB-RA-Q certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

What is the UNO-DM-3.8-TL-PLUS-US-SB-RA-Q’s DC input voltage range?

CEC tested it at 200–480 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).