Cali-GrafCali-Graf
Home battery systemSunFusion Energy Systems

SunFusion Energy Systems ECHO T Series

14–70 kWh · 9–30 kW · Lithium Ion · direct PV input · 30 configurations

UL 9540UL 1741 SBCEC listed · Jan 21, 2022
  • Nameplate energy14–70 kWh
  • Continuous power9–30 kW
  • Round trip (AC)96.5%
  • ChemistryLithium Ion

Overview

CEC Energy Storage System List

ECHO T Series: 14–70 kWh nameplate energy; 9–30 kW continuous; lithium ion; accepts solar panels directly (DC-coupled).

Models & configurations

CEC Energy Storage System List · 30 listings
ModelEnergyPowerGrid voltageRound tripCEC listed
Echo 2.0 5T {208V, 9kW, 14kWh}14 kWh9 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 9kW, 14kWh}14 kWh9 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 18kW, 14kWh}14 kWh18 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 18kW, 14kWh}14 kWh18 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 9kW, 28kWh}28 kWh9 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 9kW, 28kWh}28 kWh9 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 15kW, 28kWh}28 kWh15 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 15kW, 28kWh}28 kWh15 kW240 V96%Sep 21, 2023
Echo 2.0 5T {208V, 18kW, 28kWh}28 kWh18 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 18kW, 28kWh}28 kWh18 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 9kW, 42kWh}42 kWh9 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 9kW, 42kWh}42 kWh9 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 15kW, 42kWh}42 kWh15 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 15kW, 42kWh}42 kWh15 kW240 V96%Sep 21, 2023
Echo 2.0 5T {208V, 18kW, 42kWh}42 kWh18 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 18kW, 42kWh}42 kWh18 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 30kW, 42kWh}42 kWh30 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 30kW, 42kWh}42 kWh30 kW240 V96%Sep 21, 2023
Echo 2.0 5T {208V, 9kW, 56kWh}56 kWh9 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 9kW, 56kWh}56 kWh9 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 15kW, 56kWh}56 kWh15 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 15kW, 56kWh}56 kWh15 kW240 V96%Sep 21, 2023
Echo 2.0 5T {208V, 18kW, 56kWh}56 kWh18 kW208 V96%Jan 21, 2022
Echo 2.0 5T {240V, 18kW, 56kWh}56 kWh18 kW240 V96%Jan 21, 2022
Echo 2.0 5T {208V, 30kW, 56kWh}56 kWh30 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 30kW, 56kWh}56 kWh30 kW240 V96%Sep 21, 2023
Echo 2.0 5T {208V, 15kW, 70kWh}70 kWh15 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 15kW, 70kWh}70 kWh15 kW240 V96%Sep 21, 2023
Echo 2.0 5T {208V, 30kW, 70kWh}70 kWh30 kW208 V96%Sep 21, 2023
Echo 2.0 5T {240V, 30kW, 70kWh}70 kWh30 kW240 V96%Sep 21, 2023

Capacity & power

CEC Energy Storage System List

Charging from solar in Southern California

NLR PVWatts v8 · Cali-Graf calculation · CEC Energy Storage System List
CityDecemberJune
Los Angeles21.8 kW12.9 kW
Palmdale20.1 kW11.7 kW
Chula Vista18.6 kW13.3 kW
Huntington Beach20.5 kW14.2 kW
Riverside20.9 kW12.4 kW
Santa Clarita20.6 kW12.2 kW
Solar array size that refills the battery from empty in one average day, before the home uses any of it (NLR PVWatts v8, 20° south roof).

Safety listings

CEC Energy Storage System List
UL 9540 certifies the whole storage system; UL 9540A is the fire-propagation test that fire codes ask for indoors and near walls.

California grid & code compliance

CEC Energy Storage System List

Compare with similar batteries

CEC Energy Storage System List
BatteryEnergyContinuous powerChemistryWarrantySoCal permits
Sol-Ark L3 HVR36.9–55.3 kWh30–60 kWLithium Iron Phosphate10 years7
Sol-Ark L3 HV-xxKWH-xxK36.9–55.3 kWh30–60 kWLithium Iron Phosphate10 years—
Same segment, similar capacity; each row from the same sources.

Questions & answers

How much energy does the SunFusion Energy Systems ECHO T Series store?

14–70 kWh nameplate, per the California Energy Commission list.

Is the ECHO T Series UL 9540 certified?

Yes — the CEC list shows UL 9540 certification (certified by intertek).

Sources

  1. California Energy Commission — Energy Storage System List, data as of Oct 7, 2026. Manufacturer-reported values confirmed by CEC against certificates.
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  3. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).